Instrument Cluster Head Up Display Replacement for Buick Park Avenue 2005
Removal Procedure
- Remove the instrument panel (IP) cluster. Refer to
Instrument Cluster Replacement .
- Remove the fasteners from the head-up display (HUD) module.
- Remove the HUD module out through the IP cluster opening.
- Disconnect the electrical connector from the module.
Installation Procedure
- Connect the electrical connector to the HUD module.
- Insert the head-up display (HUD) module into the instrument panel (IP) cluster opening.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the fasteners to the HUD module.
Tighten
Tighten the fasteners to 3 N·m (26 lb in).
- Install the IP cluster. Refer to
Instrument Cluster Replacement .
- Refer to
Control Module References for programming and setup information.