Removal Procedure
- Remove the lower IP trim panel. Refer to
Instrument Panel Assembly Replacement
in Instrument Panel, Gages and Console.
- Remove the fasteners (2)
securing the heater A/C duct.
- Move the heater A/C duct aside in order to gain access to the
panel dimming control module bracket.
- Remove the module bracket
from the IP.
- Remove the panel dimming module (1) from the bracket.
- Disconnect the electrical connectors from the module.
Installation Procedure
- Connect the electrical
connectors to the module.
- Install the module (1) to the bracket.
- Install the bracket to instrument panel.
- Reposition the heater
A/C duct.
- Install the fasteners (2) securing the heater A/C duct.
- Install the lower IP trim panel. Refer to
Instrument Panel Assembly Replacement
in Instrument Panel, Gages and Console.