Removal Procedure
- Remove the right sound insulator. Refer
to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gages, and Console.
- Remove the instrument panel (I/P) storage compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Remove the I/P fuse/relay center. Refer to
Instrument Panel Electrical Center or Junction Block Replacement
in Wiring
Systems.
- Disconnect the blower motor control processor electrical connector.
- Remove the blower control processor retaining screws.
- Remove the blower control processor (1).
Installation Procedure
- Install the blower motor control processor (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws.
Tighten
Tighten the screws to 2 N·m (23 lb in).
- Connect the blower motor control processor electrical connector.
- Install the I/P fuse/relay center. Refer to
Instrument Panel Electrical Center or Junction Block Replacement
in Wiring
Systems.
- Install the I/P storage compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gages, and Console.
- Install the right sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages,
and Console.