Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Body Rear End Schematics Connector End View Reference: Body Rear End Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 | Verify that the rear hatch/gate ajar indicator is malfunctioning. Does the rear hatch/gate ajar indicator operate normally? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Is the rear hatch/gate ajar indicator always ON? | Go to Step 4 | Go to Step 6 |
4 |
Does the scan tool display Ajar? | Go to Step 5 | Go to Step 11 |
5 | Disconnect the appropriate liftgate ajar or liftglass ajar switch. Does the scan tool display Ajar? | Go to Step 8 | Go to Step 12 |
6 |
Does the scan tool display Ajar? | Go to Step 11 | Go to Step 7 |
7 |
Does the scan tool display Ajar? | Go to Step 12 | Go to Step 9 |
8 | Test the liftgate ajar switch signal circuit or the liftglass ajar switch signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 13 |
9 | Test the liftgate ajar switch signal circuit or the liftglass ajar switch signal circuit for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 10 |
10 | Test the liftgate ajar switch low reference circuit or the liftglass ajar switch low reference circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 17 | Go to Step 13 |
11 | Inspect for poor connections at the harness connector of the instrument panel cluster. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 14 |
12 | Inspect for poor connections at the harness connector of the appropriate ajar switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 15 |
13 | Inspect for poor connections at the harness connector of the liftgate module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 16 |
14 | Replace the instrument panel cluster. Refer to Instrument Cluster Replacement . Did you complete the repair? | Go to Step 17 | -- |
15 | Replace the appropriate ajar switch. Did you complete the replacement? | Go to Step 17 | -- |
16 | Replace the liftgate module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 17 | -- |
17 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |