Caution: Refer to Gasoline/Gasoline Vapors Caution in the Preface section.
Notice: Clean all of the following areas before performing any disconnections
in order to avoid possible contamination in the system:
• | The fuel pipe connections |
• | The areas surrounding the connections |
- Remove the cap on the fuel pressure service connection.
Caution: Wrap a shop towel around the fuel pressure connection in order to reduce
the risk of fire and personal injury. The towel will absorb any fuel leakage
that occurs during the connection of the fuel pressure gage. Place the towel
in an approved container when the connection of the fuel pressure gage
is complete.
- Connect the
J 42242
(1) and the
J 34730-1A
(2) to the fuel pressure service connection. Wrap a shop towel around the fitting while
connecting the gauge to avoid spillage.
- Turn the ignition ON, with the engine OFF.
Caution: Do not drain the fuel into an open container. Never store the fuel in
an open container due to the possibility of a fire or an explosion.
- Place the bleed hose of the
J 34730-1A
(2) into an approved gasoline container.
- Open the bleed valve on the
J 34730-1A
(2) in order to bleed the air from the fuel pressure gage.
- Command the fuel pump ON with a scan tool.
- Close the bleed valve on the
J 34730-1A
(2).
- Inspect for fuel leaks.