Removal Procedure
- Loosen the air cleaner outlet duct and air cleaner outlet resonator clamps (2).
- Disconnect the electrical connector from the intake air temperature (IAT)
sensor (1) .
- Disconnect the air cleaner outlet duct from the air cleaner outlet resonator.
- Disconnect the fuel pressure regulator vacuum supply from the air cleaner
outlet resonator.
- Remove the two air cleaner outlet resonator to engine bolts (4).
- Disconnect the crankcase ventilation hose (1) from the valve cover
port (2).
- Remove the air cleaner outlet resonator assembly (5) from the engine.
Installation Procedure
- Install the air cleaner outlet resonator assembly (5) to the engine making
sure of the following:
• | The crankcase ventilation hose (1) is connected to the valve cover
port (2). |
• | The air cleaner outlet resonator (5) is properly fit to the throttle
body assembly. |
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the two air cleaner outlet resonator to engine bolts (4).
Tighten
Tighten the resonator to engine bolts to 6 N·m
(53 lb in).
- Connect the fuel pressure regulator vacuum supply to the air cleaner outlet
resonator.
- Connect the air cleaner outlet duct to the air cleaner outlet resonator.
- Connect the electrical connector to the intake air temperature (IAT)
sensor (1).
- Properly position the air cleaner outlet duct and air cleaner outlet resonator
clamps (2).
Tighten
Tighten the clamps (2) to 4 N·m
(35 lb in).