Important: Place matchmarks or numbers on the connecting rod and connecting rod caps Connecting rod caps must be assembled to their original connecting rod.
J 36660-A Torque Angle Meter
Tighten
Tighten the nuts to 20 N·m (15 lb ft). Turn
the nuts evenly an additional 75 degrees usingJ 36660-A
.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
4.1. | Install all connecting rod bearings. |
4.2. | Lightly tap each connecting rod parallel to the crankpin in order to make sure the connecting rods have clearance. |
4.3. | Measure the side clearance between the connecting rod caps using a feeler gage, or dial indicator. |
4.4. | The rod side clearance should be 0.18-0.44 mm (0.007-0.017 in). |