Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the charging system check performed?
| --
| Go to
Step 2
| Refer to
Charging System Check
|
2
| Inspect the GEN fuse located in the underhood accessory
wiring junction block.
Is the GEN fuse open?
| --
| Go to
Step 3
| Go to
Step 4
|
3
|
- Replace the GEN fuse.
- Start the engine.
- Turn ON several vehicle accessories, such as headlamps and A/C.
- Stop the engine.
- Turn OFF all the vehicle electrical accessories.
- Inspect the GEN fuse again.
Is GEN fuse open again?
| --
| Go to
Step 7
| Go to
Step 4
|
4
|
- Turn the ignition switch to the OFF position.
- Disconnect the generator connector.
- Turn the ignition switch ON.
- Connect a scan tool to the Data Link Connector (DLC).
- On the scan tool, perform the following:
• | Select: Powertrain Control Module (PCM). |
• | Select: Special Functions. |
• | Select: Engine Output Controls. |
• | Select: GEN L Terminal. |
• | Command the generator ON. |
- Using J 39200
,
measure the voltage between the generator harness connector terminal B
and ground.
Is the measured voltage within the specified range?
| 5 V
| Go to
Step 5
| Go to
Step 8
|
5
| Using J 39200
, measure the voltage between the generator BAT terminal (CKT 2)
and ground.
Is the voltage measured within the specified range?
| B+ (10-14 V)
| Go to
Step 6
| Go to
Step 9
|
6
|
- Turn the ignition switch to the OFF position.
- Reconnect the generator connector.
- Verify all the vehicle electrical accessories are OFF.
- Start the engine and let it run at idle speed.
- Using J 39200
,
measure the voltage between the battery positive and negative terminals.
Is the voltage measured within the specified range?
| 13-16 V
| Go to
Step 12
| Go to
Step 7
|
7
|
- Inspect for short to ground in CKT 2740.
- If CKT 2740 is not shorted to ground, then replace the
generator. Refer to
Generator Replacement
.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|
8
|
- Turn the ignition switch to the OFF position.
- Disconnect the PCM connector C2.
- Using J 39200
,
measure the resistance between the PCM harness connector C2 terminal 61
and the generator harness connector terminal B.
Is the resistance measured within the range specified?
| Less than 2 ohms
| Go to
Step 10
| Go to
Step 11
|
9
|
- Inspect for a poor connection or an open in CKT 2.
- Inspect for a poor ground between the generator housing and the
engine. Repair as needed.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|
10
|
- The Powertrain Control Module (PCM) is not enabling CKT 225,
thus disabling the generator. Refer to
Powertrain Control Module Diagnosis
.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|
11
|
- Repair an open or a poor connection in CKT 225.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|
12
|
- Load test the generator. Refer to
Generator Not Operating Properly
.
- If the generator electrical test determines the generator output
is within specifications, then the instrument cluster is faulty causing the
charge indicator light to stay on. Refer to
Diagnostic System Check - Instrument Cluster
.
- Recheck the system.
Is the repair complete?
| --
| Go to
Charging System Check
| --
|