Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
The dome lamp does not turn on when the courtesy lights are on. | ||||
1 | Was the Interior Lights System Check performed? | -- | Go to Step 2 | Refer to Interior Lamps System Check |
2 | Was the BCM Diagnostic System Check performed? | -- | Go to Step 3 | |
3 | Inspect the dome lamp bulb filament. Is the dome lamp bulb filament open? | -- | Go to Step 5 | Go to Step 4 |
4 |
Does the test light illuminate? | -- | Go to Step 6 | Go to Step 7 |
5 | Replace the dome lamp bulb. Refer to Dome Lamp Bulb Replacement. Has the repair been made? | -- | System OK | -- |
6 | Connect a test light between the dome lamp harness connector terminal A and terminal B. Does the test light illuminate? | -- | Go to Step 8 | Go to Step 10 |
7 | Repair a poor connection or an open in circuit 1732 between the dome lamp and S386. Has the repair been made? | -- | Go to Step 9 | -- |
8 | Replace the dome lamp assembly. Refer to Dome Lamp Assembly Replacement. Has the repair been made? | -- | Go to Step 9 | -- |
9 |
Have all the repairs been made? | -- | Refer to Interior Lamps System Check | -- |
10 | Repair a poor connection or an open in circuit 157 between the dome lamp and S387. Has the repair been made? | -- | Go to Step 9 | -- |