Important: Before attempting the Fuel Tank Leak Check place a dry chemical, which
is a Class B fire extinguisher near the work area.
- Install the J 41415-40
fill tank cap adaptor.
- Connect the J 41413
EVAP pressure/purge diagnostic station to the fill tank cap adaptor.
- With a scan tool, seal the EVAP System.
- Raise the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- With the EVAP diagnostic station, maintain 15 in. H2O (3.75 kPa)
within the fuel tank.
Important: It may be necessary to partially lower the fuel tank to inspect the
top of the fuel tank and the fuel sender assembly O-ring. Refer to
Fuel Tank Replacement
.
- With the J 41416
ultrasonic leak detector, test for leaks in the fuel tank and EVAP pipes.
- Visually inspect for fuel leaking from the fuel tank.
- If a leak is detected refer to the following component replacements: