Important: To avoid misdiagnosis, complete Diagnostic Starting Point before beginning vacuum diagnosis.
• | Vacuum should be approximately 83 kPa (12 psi) with the engine running. |
• | Vacuum should remain at approximately 83 kPa (12 psi) when the engine is turned OFF. |
• | Test for vacuum to the mode valve actuators by noting the mode valve actuator position. When vacuum is applied, the actuator will retract, refer to the Air Delivery Vacuum Distribution table below. |
• | If a vacuum actuator retracts incorrectly, replace the heater-A/C control. Refer to Control Assembly Replacement . |
• | If a vacuum actuator does not retract, test for vacuum leaks, collapsed vacuum hoses or binding valves. If OK, replace the heater-A/C control. Refer to Control Assembly Replacement . |
Mode | Defrost | Heat | Heat/Defrost | Air Inlet | A/C | Abnormal Condition Reference |
---|---|---|---|---|---|---|
Off | VENT | VENT | VENT | VAC | VENT | Go to Mode Actuator Replacement or Mode Valve Replacement in Heating, Ventilation and Air Conditioning |
Max | VENT | VAC | VENT | VAC | VAC | Go to Air Inlet Actuator Replacement or Air Inlet Valve Replacement in Heating, Ventilation and Air Conditioning |
Upper | VENT | VAC | VENT | VENT | VAC | Go to Defroster Valve Actuator Replacement or Defroster Valve Replacement in Heating, Ventilation and Air Conditioning |
Bi-Level | VENT | VAC | VENT | VENT | VENT | Go to Mode Actuator Replacement or Mode Valve Replacement in Heating, Ventilation and Air Conditioning |
Lower | VENT | VAC | VAC | VENT | VENT | Go to Defroster Valve Actuator Replacement or Defroster Valve Replacement in Heating, Ventilation and Air Conditioning |
Defog | VENT | VENT | VAC | VENT | VENT | Go to Mode Actuator Replacement or Mode Valve Replacement in Heating, Ventilation and Air Conditioning |
Defrost | VAC | VENT | VAC | VENT | VENT | Go to Defroster Valve Actuator Replacement or Defroster Valve Replacement in Heating, Ventilation and Air Conditioning |