Step

Action

Value(s)

Yes

No

1

Did you review the HVAC system operation and perform the necessary inspections?

--

Go to Step 2

Go to Symptoms

2

Inspect the fuse block to determine if the HVAC fuse is open.

Is the HVAC fuse open?

--

Go to Step 3

Go to Step 6

3

  1. Disconnect the heater-A/C control harness connector C 1.
  2. Be certain the HVAC fuse is removed from the fuse block.
  3. Use a test lamp, connected to B+, to backprobe the heater-A/C control connector terminal B (CKT 41) .

Does the test lamp light?

--

Go to Step 4

Go to Step 5

4

Locate and repair a short to ground in CKT 41 (BRN). Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Step 13

--

5

  1. Reconnect the heater-A/C control
  2. Install a new HVAC CTRL fuse.
  3. Disconnect the blower motor resistor harness connector.
  4. Place the ignition switch in the RUN position.
  5. Place the fan control in the High position.
  6. Use a test lamp to probe between the blower motor resistor connector terminal F (CKT 52) and ground.

Does the test lamp light?

--

Go to Step 10

Go to Step 9

6

  1. Disconnect the blower motor connector.
  2. Turn the ignition switch to the RUN position.
  3. Turn the heater-A/C control switch to HI.
  4. Use a test lamp to backprobe between the blower motor connector, terminal A and ground.

Does the test light illuminate?

--

Go to Step 7

Go to Step 10

7

Use a test lamp to probe between the blower motor connector terminal A and terminal B.

Does the test light illuminate?

--

Go to Step 8

Go to Step 11

8

Replace the blower motor. Refer to Blower Motor and Fan Replacement .

Is the repair complete?

--

Go to Step 13

--

9

Replace the heater-A/C control. Refer to Control Assembly Replacement .

Is the repair complete?

--

Go to Step 13

--

10

  1. Disconnect the blower motor resistor connector.
  2. Use a test lamp to probe between the blower motor resistor harness connector terminal E (CKT 150) and B+.

Does the test light illuminate?

--

Go to Step 11

Go to Step 12

11

Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement .

Is the repair complete?

--

Go to Step 13

--

12

Locate and repair a poor connection or an open in CKT 150 (BLK) between the blower motor resistor connector C 1 terminal E and G200. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Step 13

--

13

Verify that the system operates properly.

Does the system operate properly?

--

System OK

Go to Symptoms