Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine Electrical.
- Remove the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel,
Gauges and Console.
- Disconnect the electrical
connector from the blower motor control module.
- Disconnect the blower
motor control module electrical connector from the blower motor.
Important: The opening to the blower motor control module is slotted. Access to
the blower motor control module opening is limited.
- Loosen both of the forward bolts.
- Remove the rearward bolt.
Important: Tilt down the rear of the blower motor control module.
- Remove the blower control module.
Installation Procedure
Important: Align the blower motor control module forward retaining slots onto bolts
and seat against HVAC module.
- Install the blower motor control module.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower motor control module rearward bolt.
Tighten
Tighten the blower motor control module bolt to 1.5 N·m
(13 lb in).
- Install the blower motor control module forward bolts.
Tighten
Tighten the blower motor control module bolts to 1.5 N·m
(13 lb in).
- Connect the blower motor
control module electrical connector to the blower motor.
- Connect the electrical
connector from the blower motor control module.
- Install the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel,
Gauges and Console.
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine Electrical.