🢒 Hazard and Turn Signal Flasher Replacement
Removal Procedure
Remove the LH instrument panel (IP) insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gages and Console.
Remove the steering column filler panel. Refer to
Steering Column Opening Filler Replacement
in Instrument Panel, Gages and Console.
Grasp the hazard and turn signal flasher and slide the flasher to the right to release the flasher tabs from the slots on the BCM bracket.
Disconnect the electrical connector from the hazard and turn signal flasher.
Installation Procedure
Connect the electrical connector to the hazard and turn signal flasher.
Position the flasher to the BCM bracket, then slide the flasher to the left to secure the flasher tabs into the retaining slots on the bracket.
Install the steering column filler panel. Refer to
Steering Column Opening Filler Replacement
in Instrument Panel, Gages and Console.
Install the LH IP insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gages and Console.