Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the system operation? | -- | Go to Step 2 | Go to Symptoms |
2 | Using a scan tool, establish communication with the CD player. Does the CD player work remotely through the scan tool? | -- | Go to Step 3 | Go to Step 4 |
3 | Inspect for a open in the E&C serial bus circuit, between the radio and the CD player. Refer to Circuit Testing and Wiring Repairs in Wiring Systems for service procedure. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 |
4 | Inspect the CD player B+ feed circuit for a open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems for service procedure. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 |
5 | Inspect the CD player ground circuit for a open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems for service procedure. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 7 |
6 | Replace the Radio. Refer to Radio Replacement for service procedure. Did you complete the replacement? | -- | Go to Step 8 | -- |
7 | Service the remote CD changer and replace if necessary Did you complete the replacement? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |