Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the FEIC Mode data change? | -- | Go to Step 3 | |
3 |
Is the measured voltage the same as the specified value? | B+ | Go to Step 4 | Go to Step 6 |
4 | Using a DMM, test terminal 2 circuit 1550 (BLK) for an open. Is circuit 1550 open? | -- | Go to Step 7 | Go to Step 5 |
5 |
Does the FEIC Mode data change ? | -- | Go to Step 8 | Go to Step 9 |
6 | Repair open or poor connection in circuit 893 (PNK). Did you complete the repair and test the system? | -- | -- | |
7 | Repair open or loose terminal in circuit 1550 (BLK). Did you complete the repair and test the system? | -- | -- | |
8 | Replace the DIC switch assembly. Did you complete the repair and test the system? | -- | -- | |
9 | Replace the IP cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | -- |