- Using a small screwdriver, pry the wiring
harness (224/225) electrical connectors off of the following components:
• | Automatic transaxle fluid pressure manual valve position switch
assembly (395) |
• | 1-2, 3-4 Shift solenoid valve assembly (315A) |
• | 2-3 Shift solenoid valve assembly (315B) |
• | TCC PWM solenoid valve assembly (334) |
• | Pressure control solenoid valve assembly (322) |
• | Automatic transaxle input speed sensor assembly (440) |
- Gently pull the automatic transaxle fluid temperature sensor (391)
from it's clip.
- Lift the wiring harness assembly (224/225)
off of the transaxle.