Important: Do not remove any of the bore plugs unless inspection indicates that
replacement is necessary.
- Remove the manual valve (404).
- Remove the 3-4 accumulator piston cylinder (421) and the 3-4 accumulator
piston O-ring seal (422). Use low pressure compressed air from the valve body
side if necessary for removal.
- Remove the 3-4 accumulator piston outer spring (423) and inner
spring (424).
- Remove the 3-4 accumulator piston (428).
- Remove the 3-4 accumulator piston pin (426) from the valve body
side of the case cover (401).
Caution: Valve Springs can be tightly compressed. Use care when removing retainers
and plugs. Personal injury could result.
- Remove the actuator feed limit valve spring retainer (416).
- Remove the actuator feed limit valve spring (415).
- Remove the actuator feed limit valve (414).