Removal Procedure
- Remove the case side cover. Refer to
Control Valve Body Cover Replacement
.
- Disconnect the 1-2 shift solenoid electrical connector.
- Remove the 1-2 shift solenoid (315A).
Installation Procedure
- Install the 1-2 shift solenoid (315A).
- Connect the 1-2 shift solenoid electrical connector.
- Install the case side cover. Refer to
Control Valve Body Cover Replacement
.
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function
.