Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls-3.1L or
Air Cleaner Assembly Replacement
in Engine Controls-3.8L.
- Disconnect the A/C refrigerant pressure sensor from the electrical connector.
- Remove the A/C refrigerant pressure sensor from the condenser tube.
Installation Procedure
- Install the new O-ring seal. Refer to
O-Ring Replacement
.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the A/C refrigerant pressure sensor to the condenser tube.
Tighten
Tighten the sensor to 4.7 N·m (41 lb in).
- Connect the A/C refrigerant pressure sensor to the electrical connector.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls-3.1L or
Air Cleaner Assembly Replacement
in Engine Controls-3.8L.
- Leak test the fittings of the component usingJ 39400-A
.