Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions.
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Value(s) | Yes | No | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? |
| Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature AT THE TIME OF THE TEST.
Important: When performing this step it is necessary to press the RESET button on the J 43600 before pressing the PRINT button.
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||||
6 | Are the low and high side pressures both higher than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic in HVAC Systems - Automatic |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 175-243 kPa (25-35 psi) | 640-990 kPa (93-144 psi) | 12°C (53.6°F) |
19-24°C (66-75°F) | Below 40% | 175-256 kPa (25-37 psi) | 750-1120 kPa (109-163 psi) | 12°C (53.6°F) |
Above 40% | 184-287 kPa (27-42 psi) | 820-1240 kPa (119-180 psi) | 15°C (59°F) | |
25-29°C (76-85°F) | Below 35% | 196-277 kPa (28-40 psi) | 960-1280 kPa (139-186 psi) | 14°C (57.2°F) |
35-60% | 212-290 kPa (31-42 psi) | 1020-1340 kPa (148-195 psi) | 16°C (60.8°F) | |
Above 60% | 223-316 kPa (32-46 psi) | 1070-1460 kPa (155-212 psi) | 18°C (64.4°F) | |
30-35°C (86-95°F) | Below 30% | 220-303 kPa (32-44 psi) | 1130-1480 kPa (164-215 psi) | 17°C (62.6°F) |
30-50% | 223-322 kPa (34-47 psi) | 1190-1570 kPa (173-228 psi) | 19°C (66.2°F) | |
Above 50% | 250-350 kPa (36-51 psi) | 1260-1710 kPa (183-248 psi) | 21°C (69.8°F) | |
36-41°C (96-105°F) | Below 20% | 245-324 kPa (36-47 psi) | 1300-1630 kPa (189-237 psi) | 19°C (66.2°F) |
20-40% | 254-344 kPa (37-50 psi) | 1350-1750 kPa (196-254 psi) | 21°C (69.8°F) | |
Above 40% | 273-364 kPa (40-53 psi) | 1440-1860 kPa (209-270 psi) | 23°C (73.4°F) | |
42-46°C (106-115°F) | Below 20% | 273-348 kPa (40-51 psi) | 1440-1860 kPa (209-270 psi) | 22°C (71.6°F) |
Above 20% | 284-370 kPa (41-54 psi) | 1550-1930 kPa (218-261 psi) | 24°C (75.2°F) | |
47-49°C (116-120°F) | Below 30% | 308-374 kPa (45-54 psi) | 1720-1970 kPa (250286 psi) | 24°C (75.2°F) |