The number(s) below refer to the step number(s) on the diagnostic table.
Tests for voltage at the vacuum control assembly.
Verifies that the HVAC control module is providing ground to the vacuum control assembly.
Tests if ground is constantly being applied to the vacuum control assembly.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the scan tool indicate the Recirculate Button parameter changes state? | -- | Go to Step 3 | Go to Step 10 |
3 |
Does the recirculation door move from the recirculation position to the outside air position? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 4 |
Does the test lamp illuminate? | -- | Go to Step 5 | Go to Step 11 | |
Does the measured voltage change between the specified values? | 12 V ON 0 V OFF | Go to Step 9 | Go to Step 6 | |
Does the measured voltage remain near the specified value? | 12 V | Go to Step 8 | Go to Step 7 | |
7 | Test the recirculation mode valve solenoid control circuit of the vacuum control assembly for a short to voltage or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 10 |
8 | Test the recirculation mode valve solenoid control circuit of the vacuum control assembly for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 9 |
9 | Inspect for poor connections at the harness connector of the vacuum control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 12 |
10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 13 |
11 | Repair the ignition 3 voltage circuit of the vacuum control assembly for an open or high resistance. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 14 | -- |
12 | Replace the vacuum control assembly. Refer to Vacuum Control Assembly Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- |
13 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- |
14 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 4 |