Removal Procedure
- Remove the right instrument panel insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gages and Console.
- Remove the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages and
Console.
- Disconnect the two vacuum
lines from the defroster actuator (3).
- Disconnect the orange vacuum line from the recirculation actuator
and install a hand vacuum pump (2).
- Remove the defroster actuator from the attachment to the HVAC
module case.
- Using the hand vacuum pump (2), open the recirculation
actuator door to the full open position.
- Rotate the defroster actuator to the right and up into the opening
between the back of the dash and the opening into the HVAC module.
- Disconnect the defroster actuator from the defroster door arm.
Installation Procedure
- Install the defroster
actuator to the defroster door arm and snap into place on the HVAC module.
- Connect the vacuum line to the actuator.
- Remove the hand vacuum pump (2) and reinstall the vacuum
line to the recirculation actuator.
- Install the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages and
Console.
- Install the right instrument insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gages and Console.