• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ terminal 30 | 1 | 1 | -- | -- |
ECM Park/ Neutral Signal | 2 | 1 | -- | -- |
Coil Control terminal 86 | -- | 1 | 3 | -- |
Control Output terminal 87 | 1 | 1 | 3 | -- |
Coil Ground terminal 85 | -- | 1 | -- | -- |
1. No crank 2. Cranks in any gear 3. Cranks all the time |
When the ignition mode switch is placed in the START position, a discrete signal is supplied to the body control module (BCM) notifying it that the ignition is in the START position. The BCM then sends a serial data message to the engine control module (ECM) that crank has been requested. The ECM verifies that the automatic transmission is in Park/Neutral. If it is, the ECM then supplies 12 volts to the control circuit of the starter relay. When this occurs, battery voltage is supplied through the switch of the starter relay to the starter solenoid.
Starting System Description and Operation
Control Module References for scan tool information
⇒ | If DTCs are set, refer to Diagnostic Trouble Code (DTC) List - Vehicle |
⇒ | If not the specified value, refer to Power Mode Description and Operation |
⇒ | If the TCM IMS parameter does not indicate Park/Neutral. Refer to Transmission Internal Mode Switch Logic |
⇒ | If the ECM Park/Neutral parameter does not indicate Park/Neutral. Refer to ECM Park Switch Circuit Malfunction. |
⇒ | If the starter relay does not click or the engine does not crank, refer to Starter Relay Circuit Malfunction. |
⇒ | If not the specified value, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If the solenoid does not engage, test the control output circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the starter motor. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |