• | Perform the Diagnostic System Check - VehicleDiagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based DiagnosisStrategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure InstructionsDiagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ambient Air Temperature Sensor Signal | B0158 02 | B0158 05 | B0158 05 | -- |
Low Reference | -- | B0158 05 | B0158 05 | -- |
The instrument cluster monitors the ambient air temperature sensor with a low reference circuit and 5-volt signal circuit. The instrument cluster monitors the voltage drop across the sensor, which is proportional to temperature. When the ambient air temperatures are cold, the resistance of the sensor is high and the voltage signals are high. When the ambient air temperatures are hot, the resistance of the sensors is low and the voltage signals are low. The instrument cluster converts the voltage value to a temperature value of Celsius or Fahrenheit that will be displayed by the driver information center.
Instrument Cluster SchematicsInstrument Cluster Schematics
Component Connector End ViewsComponent Connector End Views
Driver Information Center (DIC) Description and Operation
• | Circuit TestingCircuit Testing |
• | Connector RepairsConnector Repairs |
• | Testing for Intermittent Conditions and Poor ConnectionsTesting for Intermittent Conditions and Poor Connections |
• | Wiring RepairsWiring Repairs |
Control Module ReferencesControl Module References for scan tool information
Ignition ON, observe the scan tool Ambient Air Temperature parameter. The reading should be between -40°C (-40°F) and 88°C (190°F) and change with air temperature changes.
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the P16 Instrument Cluster. |
⇒ | If greater than the specified range, test the signal circuit terminal 1 for a short to voltage. If the circuit tests normal, replace the P16 Instrument Cluster. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the P16 Instrument Cluster. |
⇒ | If not within the specified range, replace the B9 Ambient Air Temperature. |
Perform the Diagnostic Repair VerificationDiagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module ReferencesControl Module References for instrument cluster replacement, setup, and programming |