• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage |
---|---|---|---|
5 V Reference Voltage | P0107, P0193, P0237, P0642 | P0193 | P0193, P0643, P0236 |
FRP Sensor Signal | P0192 | P0193 | P0193 |
Low Reference | -- | P0193 | P0193, P0236, P0643 |
The fuel rail pressure (FRP) sensor detects fuel pressure within the fuel rail. The engine control module (ECM) provides a 5V reference voltage on the 5V reference circuit and ground on the reference ground circuit. The ECM receives a varying signal voltage on the signal circuit. The ECM monitors the voltage on the FRP sensor circuits. When the fuel pressure is high, the signal voltage is high. When the fuel pressure is low, the signal voltage is low.
• | DTCs P0097, P0098, P0099, P0117, P0118, P0192, P0193, P0627, P0628, P0692 are not set. |
• | The ignition is ON or the engine is running. |
• | The DTCs run continuously within the enabling conditions. |
The ECM detects that the signal circuit voltage is less than 0.3V for 1 second.
The ECM detects that the signal circuit voltage is greater than 4.7V for 1 second.
• | DTCs P0192 and P0193 are Type B DTCs. |
• | A message center or an indicator displays Reduced Engine Power when DTC P0192 or P0193 sets. |
DTCs P0192 and P0193 are Type B DTCs.
A poor connection, improper terminal contact, or improper terminal retention at the X145 multi-way harness connector may set DTC P0193.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the K20 ECM. |
⇒ | If less than the specified range, test the 5V reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K20 ECM. |
⇒ | If greater than the specified range, test the 5V reference circuit for a short to voltage. If the circuit tests normal, replace the K20 ECM. |
⇒ | If the specified parameter does not toggle between the minimum and maximum values, test the signal circuit for a short to voltage, short to ground, or an open/high resistance. If the circuit tests normal, replace the K20 ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |