• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Stepper Motors 12 V Reference | B023A 02, B0223 06, B022A 06, B0233 06, B0408 06, B0418 06 | B0223 06, B022A 06, B0233 06, B0408 06, B0418 06 | -- | -- |
Mode Actuator Control 1 | B0233 06 | B0233 06 | B0233 01 | 1 |
Mode Actuator Control 2 | B0233 06 | B0233 06 | B0233 01 | 1 |
Mode Actuator Control 3 | B0233 06 | B0233 06 | B0233 01 | 1 |
Mode Actuator Control 4 | B0233 06 | B0233 06 | B0233 01 | 1 |
1. Air Distribution Malfunction |
With the defrost switch, air to foot well switch, air to windscreen switch and the air to head area switch at the HVAC control, the wished air distribution flap position can be put in. The selected value is sent to the HVAC control module via LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor puts the air distribution flap into the selected position.
Check the following mechanical fault sources:
• | Air distribution box |
• | Air distribution hoses / air distributing ducts |
LINK 49327
Automatic HVAC Description and Operation
Control Module References for scan tool information
⇒ | If not the specified value, replace the A26 HVAC Control. |
⇒ | If not the specified value, replace the A26 HVAC Control. |
⇒ | If not the specified value, replace the A26 HVAC Control. |
⇒ | If not the specified value, replace the A26 HVAC Control. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | LINL 63253 |
• | Control Module References for HVAC control module replacement, setup, and programming |