• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ | B1517 03, B1517 5A | B1517 03, B1517 5A | -- | -- |
B+ high resolution | B1517 03, B1517 5A | B1517 03, B1517 5A | -- | -- |
Ground | -- | B1517 03, B1517 5A | -- | -- |
The body control module (BCM) has designated circuits for monitoring vehicle system voltage. The BCM monitors the system voltage to ensure that the voltage stays within the proper range. Damage to components, and incorrect data may occur when the system voltage is out of range. The BCM monitors the system voltage over an extended length of time. If the BCM detects the system voltage is outside an expected range for the calibrated length of time, or the 2 BCM battery sense circuits differ by 2 V, DTC B1517 A will set.
• | The BCM has power and ground. |
• | The ignition is not in the START position. |
• | The battery voltage is less than 11 V. |
• | The engine speed is greater than 1,100 RPM. |
• | The above conditions are met for 15 seconds. |
• | The battery voltage is greater than 16 V. |
• | The engine speed is greater than 1,100 RPM. |
• | The above conditions are met for 15 seconds. |
The battery voltage differs by 2 V on the BCM battery sense circuits for 10 seconds.
• | The instrument panel cluster (IPC) illuminates the charge indicator. |
• | The driver information center (DIC) displays the SERVICE BATTERY CHARGING SYSTEM warning message. |
• | The DTC will clear current status when fault is no longer present. |
• | The history DTC will clear after 50 consecutive ignition cycles have occurred without a malfunction. |
• | A high or low voltage DTC set in multiple modules indicates a concern in the charging system. Refer to Charging System Test |
• | This DTC may be set by overcharging with a battery charger, or jump by starting. |
• | Inspect the ground connection G201, and ensure that it is clean and tight. |
Charging System Description and Operation
Control Module References for scan tool information
⇒ | If not within the specified range, refer to Charging System Test |
⇒ | If not within the specified range, test the ground circuit for an open/high resistance. |
• | Terminal |
• | Terminal |
⇒ | If the test lamp does not illuminate, test the B+ circuits for a short to ground or an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for BCM replacement, setup, and programming.