Removal Procedure
Important: The ignition switch must be in the OFF position when removing the instrument
panel cluster.
- Remove the instrument
panel cluster trim plate. Refer to
Instrument Cluster Trim Panel Replacement
.
- Remove the screws from the instrument panel cluster.
- Rotate the top of the instrument panel cluster rearward and disengage
the locating pins on the bottom of the instrument panel cluster.
- Disconnect the electrical
connector from the instrument panel cluster.
- Remove the instrument panel cluster from the instrument panel.
Installation Procedure
- Connect the electrical
connector to the instrument panel cluster.
- Position the locating
pins on the bottom of the instrument panel cluster to the pin receivers in
the instrument panel.
- Install the instrument panel cluster rotating the top of the instrument
panel cluster forward and engage the locating pins on the bottom of the instrument
panel cluster.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the instrument
panel cluster.
Tighten
Tighten the instrument panel cluster screws to 2 N·m (18 lb in).
- Install the instrument panel cluster trim plate. Refer to
Instrument Cluster Trim Panel Replacement
.