Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Diagnostic System Check for starting and charging? | Go to Step 2 | |
2 | Start the engine. Does the charge indicator lamp remain ON? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 |
Does the scan tool indicate that the Volt Lamp parameter is ON? | Go to Step 4 | Go to Charging System Test |
4 | Inspect for poor connections at the harness connector of the IPC. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition | Go to Step 6 | Go to Step 5 |
5 | Replace the IPC. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console. Did you complete the replacement? | Go to Step 6 | -- |
6 | Operate the system for which the symptom occurred. Did you correct the condition? | System OK | Go to Step 2 |