Step
| Action
| Value(s)
| Yes
| No
|
1
| Check the
blower electrical connections and the grounds.
Is the action complete?
| --
|
Go to Step
2
| --
|
2
|
- Sit inside the vehicle.
- Close all doors and windows.
- Turn the ignition switch to ON.
- Set the blower speed to HI.
- Set the mode to VENT.
- Set the temperature control to full COLD.
- Cycle through all blower speeds, modes and temperature control
positions to determine where noise occurs and where it does not occur.
Is the blower making a constant whine, tick/click, flutter or scrapping
noise but it lessens with a lower blower speed?
| --
|
Go to Step 4
|
Go to Step 3
|
3
| Listen to the blower again.
Is the blower making a squeal/screech noise at start-up only and/or
sometimes intermittent?
| --
|
Go to Step 4
|
Go to Step 7
|
4
| Check for blower
motor and the fan vibration at each blower speed by feeling blower case.
Is the vibration excessive?
| --
|
Go to Step
6
|
Go to Step 5
|
5
|
- Remove the blower from blower case.
- Check for foreign material at opening of blower intake.
Was foreign material found?
| --
|
Go to Step
10
|
Go to Step 6
|
6
|
- Check the blower fan for the following conditions:
- Check the blower case for wear spots.
Was any wear found?
| --
|
Go to Step
11
|
Go to Step 12
|
7
|
- Set the blower speed to HI.
- Check the full HOT to full COLD temperature positions in VENT,
HEAT and DEFROSTER modes.
Is excessive blower noise in VENT mode only?
| --
|
Go to Step 13
|
Go to Step 8
|
8
| Listen to the blower again.
Is excessive blower noise in HEAT and/or DEFROST modes only?
| --
|
Go to Step 14
|
Go to Step 9
|
9
| Listen to blower again.
Is excessive blower noise in HEAT and/or DEFROST modes only?
| --
|
Go to Step 15
|
Go to Step 16
|
10
|
- Remove the foreign material from blower assembly.
- Repair as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
11
| Repair the blower fan and/or blower case as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
12
| Replace the blower motor and fan.
Is the action complete?
| --
|
Go to Step
17
| --
|
13
|
- Check the air ducts for obstructions and foreign material.
- Check the vent door seals.
- Repair as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
14
|
- Check the air ducts for obstructions and foreign material.
- Check the heater and/or defroster door seals.
- Repair as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
15
|
- Check the temperature door seals.
- Repair as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
16
|
- Check the heater system for obstructions or foreign material between
the blower fan and the temperature door.
- Repair as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
17
| Perform the functional test. Refer to
Functional Check
.
Is the action complete?
| --
| System OK
| --
|