Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did the VDOT System Performance Test refer further diagnosis to the VDOT Refrigerant Charge? | -- | Go to Step 2 | Go to System Performance Test |
2 |
Are the high and low side pressures approximately equal to the specified value? | 345 kPa (50 psi) | Go to Step 3 | |
3 | Are the high and low side pressures above the specified value ? | 345 kPa (50 psi) | System OK | Go to Step 4 |
4 |
Is there a leak? | -- | Go to Step 6 | Go to Step 5 |
5 | Are the high and low side pressures between the specified value ? | 207-345 kPa (30 -50 psi) | System OK | Go to Step 6 |
6 | Repair the leak. Is the repair complete? | -- | Go to Step 7 | -- |
7 | Evacuate and charge the A/C system. Refer to Refrigerant Recovery and Recharging . Are the high and low side pressures above the value specified? | 345 kPa (50 psi) | System OK |