Temperature Actuator Replacement Front LH
Removal Procedure
- Remove the knee bolster. Refer to
Knee Bolster Replacement
in Instrument Panel, Gauges and Console.
- Disconnect the electrical
connector from the temperature actuator.
- Remove the mounting screws from the temperature actuator.
- Remove the temperature
actuator.
Installation Procedure
- Position the temperature
actuator, then align the slots in the electric actuator driver to the
flats on the temperature valve shaft.
- Slide the electric actuator driver onto the shaft, while aligning
the actuator locating hole to the forward alignment pin on the HVAC module
case. The actuator driver should completely seat onto the temperature
valve shaft and the mounting holes should be flush with the mounting
bosses on the HVAC module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mounting
screws to the temperature actuator.
Tighten
Tighten the temperature actuator screws to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the temperature actuator.
- Install the knee bolster. Refer to
Knee Bolster Replacement
in Instrument Panel, Gauges and Console.
Temperature Actuator Replacement Rear CJ4
Removal Procedure
- Remove the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in
Instrument Panel, Gauges and Console.
- Remove the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gauges and Console.
- Disconnect the electrical
connector from the RH temperature valve electric actuator.
- Remove the screws retaining
the RH temperature valve electric actuator.
- Remove the electric actuator.
Installation Procedure
- Position the temperature
actuator, then align the slots in the electric actuator driver to the
flats on the temperature valve shaft.
- Slide the temperature actuator driver onto the shaft, while aligning
the actuator locating holes to the forward alignment pin on the HVAC module
case. The actuator driver should completely seat onto the temperature
valve shaft and the mounting holes should be flush with the mounting
bosses on the HVAC module case.
- Install the retaining screws.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the temperature actuator.
Tighten
Tighten the temperature actuator screws to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the temperature valve electric actuator.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gauges and Console.
- Install the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in
Instrument Panel, Gauges and Console.