Removal Procedure
- Remove the right instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel,
Gauges and Console
- Remove the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gauges and Console.
- Disconnect the vacuum line from the air inlet vacuum actuator.
- Lift to release the air inlet vacuum actuator retaining tab and
slide off mounting bracket.
- Disconnect the vacuum
actuator plunger rod from the air inlet valve lever and remove the vacuum
actuator.
Installation Procedure
- Connect the vacuum actuator
plunger rod to the air inlet valve, then extend the plunger.
Important: During installation, ensure that the air inlet vacuum actuator retaining
tab is positioned above the mating base on the HVAC module case.
- Push the vacuum actuator toward the HVAC module case to secure the retaining
tab.
Important: Check that the vacuum actuator pushrod is not binding on the air inlet
lever.
- Connect the vacuum harness connector to the air inlet vacuum actuator.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gauges and Console.
- Install the right instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel,
Gauges and Console