GM Service Manual Online
For 1990-2009 cars only

Vacuum Electrical Solenoid Replacement CJ4

Removal Procedure

  1. Remove the right side instrument panel insulator. Refer to Instrument Panel Insulator Replacement in Instrument Panel, Gauges and Console.

  2. Object Number: 295337  Size: SH
  3. Disconnect the electrical connector from the vacuum electric solenoid.

  4. Object Number: 295340  Size: SH
  5. Disconnect the vacuum harness connector from the vacuum electric solenoid.

  6. Object Number: 295343  Size: SH
  7. Remove the vacuum electric solenoid mounting screws.
  8. Important: Pull the vacuum electric solenoid straight down to release the tab from the slot in the HVAC module case.

  9. Remove the vacuum electric solenoid.

Installation Procedure


    Object Number: 295343  Size: SH
  1. Align the vacuum electric solenoid valve tab to the slot in the HVAC module case, then push up to seat the vacuum electric solenoid.
  2. Install the retaining screws.
  3. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  4. Install the vacuum electric solenoid mounting screws.
  5. Tighten
    Tighten the vacuum electric solenoid screws to 1.5 N·m (13 lb in).


    Object Number: 295340  Size: SH
  6. Connect the vacuum harness connector to the vacuum electric solenoid.

  7. Object Number: 295337  Size: SH
  8. Connect the electrical connector to the vacuum electric solenoid.
  9. Install the right side instrument panel insulator. Refer to Instrument Panel Insulator Replacement in Instrument Panel, Gauges and Console.