Step
| Action
| Normal Result(s)
| Abnormal Result(s)*
|
1
|
- Turn the ignition switch to the OFF position.
- Turn the ignition switch to the RUN position.
|
• | The defogger ON indicator is off. |
|
Defoggers and Heated Mirrors Always On
|
2
|
- Press and release the defogger switch one time.
- Wait approximately 11 minutes.
|
• | The defogger ON indicator turns on. |
• | The defoggers turns on. |
• | The defogger ON indicator and the defoggers turn off after approximately
10 minutes. |
|
|
3
|
- Press and release the defogger switch one time.
- Wait approximately 6 minutes.
|
• | The defogger ON indicator turns on. |
• | The defogger ON indicator and the defoggers turn off after approximately
5 minutes. |
|
Rear Window Defogger Inoperative
|
4
|
- Press and release the defogger switch one time.
- Wait approximately 15 seconds.
- Press and release the defogger switch a second time. Complete
this action before time-out occurs.
|
- The defogger ON indicator turns on.
- The defoggers turn on.
- Pressing the switch for the second time causes the defogger ON
indicator and the defoggers to turn off immediately.
|
Defoggers and Heated Mirrors Always On
|
* Refer to the appropriate symptom diagnostic table for the applicable abnormal
result.
|