Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Noise originating from the blower motor and/or the air delivery
system. No loss of battery or ground is occurring in the blower motor circuit.
The blower motor resistor and the blower motor are not exhibiting
any intermittent internal shorts. For electrical diagnosis of the
blower motor circuit, refer to
Blower Motor Inoperative at Any Speed
in HVAC
Systems -- Manual.
|
1
| Were you sent here from the HVAC Symptoms?
| --
| Go to
Step 2
| Go to
Symptoms - HVAC Systems - Manual
in HVAC Systems --
Manual
|
2
|
- Sit inside the vehicle.
- Close the vehicle doors and windows.
- Turn the ignition switch to ON; engine OFF.
- Turn the blower switch to high.
- Set the temperature control to full cold.
- Set the mode control to UPPER (I/P outlets).
- Cycle through all the blower motor speeds, modes (including outside
air and recirc) and temperature control positions to determine where noise
occurs and where noise does not occur.
- Attempt to define the type of noise:
• | Tick/click, chirping, groaning, scraping |
Is a scrape or pop noise evident when selecting modes or temperature
settings (moving a mode or temperature door)?
| --
| Go to
Step 12
| Go to
Step 3
|
3
| Is a tick/click, chirping, groaning or scraping noise present
-- constantly but decreases as blower motor speed is decreased, or
only at start-up/intermttent -- in all modes?
| --
| Go to
Step 6
| Go to
Step 4
|
4
| Is an air rush/whistle noise evident in all
modes but not all temperature settings?
| --
| Go to
Step 13
| Go to
Step 5
|
5
| Is an air rush/whistle noise evident only in defrost or lower mode?
| --
| Go to
Step 14
| Go to
Step 15
|
6
| Inspect for blower motor
and impeller assembly excessive vibration at each blower motor speed by
feeling the blower case.
Is excessive vibration present?
| --
| Go to
Step 7
| Go to
Step 9
|
7
|
- Remove the blower motor. Refer to
Blower Motor and Fan Replacement
.
- Examine the blower motor impeller for the following conditions:
• | Deposits of foreign material |
• | Loose impeller retainer |
• | Improper impeller alignment |
Does the blower motor impeller exhibit any of these abnormal conditions?
| --
| Go to
Step 8
| Go to
Step 9
|
8
|
- Repair or replace the blower motor impeller.
- Install the blower motor. Refer to
Blower Motor and Fan Replacement
.
Is the action complete?
| --
| Go to
Step 16
| --
|
9
|
- Remove the blower motor. Refer to
Blower Motor and Fan Replacement
.
- Inspect for the presence of foreign material at the opening of
the blower intake.
Was foreign material found?
| --
| Go to
Step 11
| Go to
Step 10
|
10
|
- Replace the blower motor.
- Install the blower motor. Refer to
Blower Motor and Fan Replacement
.
Is the repair complete?
| --
| Go to
Step 17
| --
|
11
|
- Remove the foreign material from the blower case.
- Repair as necessary.
Is the action complete?
| --
| Go to
Step 17
| --
|
12
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in
Instrument Panel, Gauges and Console.
- Inspect the defroster, mode, air inlet and temperature door function.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step 17
| --
|
13
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in
Instrument Panel, Gauges and Console.
- Inspect the temperature door seals.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step 17
| --
|
14
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in
Instrument Panel, Gauges and Console.
- Inspect the ducts for obstructions or foreign materials.
- Remove any obstructions or foreign material found.
- Inspect the defroster door function.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step 17
| --
|
15
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Upper Trim Pad Replacement
in
Instrument Panel, Gauges and Console.
- Inspect the ducts for obstructions or foreign materials.
- Remove any obstructions or foreign material found.
- Inspect the defroster door seals.
- Repair or replace as necessary.
Is the action complete?
| --
| Go to
Step 17
| --
|
16
|
- Turn OFF the ignition switch.
- Reconnect or install any connectors or components which were disconnected
or removed.
- Reinspect for the presence of blower motor/air delivery system
noise.
Is the noise still present?
| --
| Go to
Step 10
| Go to
Blower Motor Inoperative at Any Speed
in HVAC Systems --
Manual
|
17
|
- Turn OFF the ignition switch.
- Reconnect or install any connectors or components which were disconnected
or removed.
- Reinspect for the presence of blower motor/air delivery system
noise.
Is the noise still present?
| --
| Go to
Step 2
| Go to
Blower Motor Inoperative at Any Speed