Test Description

  1. This checks for A/C compressor clutch always OFF.

  2. This test is to ensure A/C system is operating normally.

Step

Action

Value(s)

Yes

No

Schematic Reference: HVAC Air Delivery/Temperature Control Schematics

Definition: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation.

1

Did you perform the HVAC Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check

2

  1. Disconnect the scan tool.
  2. Turn OFF the ignition.
  3. Recalibrate actuators.
  4. Install a scan tool.
  5. Turn ON the ignition, with the engine OFF.
  6. Observe the Diagnostic Trouble Code (DTC) List in Heating, Ventilation and Air Conditioning.

Does the scan tool display any DTC B0361, B0363, B0365, B0367, B0441 or B0446?

--

Go to DTC Table

Go to Step 3

3

Important:: Ambient air temperature must be above 3°C (38°F).

  1. Cover the sunload sensor.
  2. Start the engine.
  3. Fully open all panel outlets.
  4. Place the temperature switch in the coldest position.
  5. Place the mode switch in the bi-level position.
  6. Place the blower motor switch in the maximum speed position.
  7. Ensure that the VENT mode indicator is not illuminated.

Does the A/C compressor operate?

--

Go to Step 4

Go to HVAC Compressor Clutch Does Not Engage

4

Place the blower motor switch in each speed position.

Does the blower motor operate in any of the speed positions?

--

Go to Step 5

Go to Blower Motor Inoperative

5

Does the blower motor operate in the desired speed(s)?

--

Go to Step 6

Go to Blower Motor Malfunction

6

  1. Place the blower motor switch in the maximum speed position.
  2. Place the mode switch in the vent position.
  3. Place the recirculation switch in the ON and OFF positions.

Does the recirculation door move from the recirculation position to the outside air position?

--

Go to Step 7

Go to Air Recirculation Malfunction

7

Perform the refrigerant system performance test. Refer to System Performance Test in Heating, Ventilation and Air Conditioning.

Are low and high side pressures within specifications?

--

Go to Step 8

Go to Leak Testing in Heating, Ventilation and Air Conditioning

8

  1. Turn ON the ignition, with engine OFF.
  2. With a scan tool, command the right and left air temperature actuators Hot and Cold.
  3. Observe the Right Temp Door Position and the Left Temp Door Position parameters.

Do the counts change when actuators are commanded?

--

Go to Step 9

Go to Step 16

9

  1. Install a thermometer near the inside air temperature sensor.
  2. With a scan tool, observe the Inside Air Temp data parameters in the Heating and A/C Data list.

Does the scan tool indicate sensor temperature near the thermometer temperatures within the specified range?

-3 to +3°C (-5 to +5°F)

Go to Step  11

Go to Step  10

10

Inspect for a blocked, malfunctioning, or incorrectly installed inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement

Did you find and correct the condition?

--

Go to Step  25

Go to Step  14

11

  1. Turn the engine OFF.
  2. Install a scan tool.
  3. Cover the sunload sensor.
  4. Start the engine.
  5. Adjust driver side temperature to 22°C (72°F).
  6. With a scan tool, observe the Solar Sensor data parameter in the Heating, Ventilation and Air Conditioning data list.

Does the scan tool indicate that the Solar Sensor parameter is greater than the specified value?

230  Counts

Go to Step  12

Go to Step  19

12

  1. Uncover the sunload sensor.
  2. Direct a light source at the sunload sensor.

Does the voltage change?

--

Go to Step  13

Go to Step  19

13

Does the customer need to change the set temperature frequently to maintain comfort?

--

Go to Symptoms - HVAC Systems - Automatic

System OK

14

Inspect for poor connections at the harness connector of the inside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step  25

Go to Step  15

15

  1. Turn OFF the ignition.
  2. Test the inside air temperature sensor resistance. Refer to Sensor Resistance Table .

Does the resistance measure near the specified value?

--

Go to Step  20

Go to Step  21

16

Test the suspect actuator door control circuits, circuit 1199 of the left air temperature actuator and circuit 1236 of the right air temperature actuator for a short to voltage, short to ground, open or high resistance. Refer to Circuit Testing and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step  25

Go to Step  17

17

Test the circuit 41 of the suspect air temperature actuator for a short to ground, open or high resistance. Refer to Circuit Testing and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step  25

Go to Step  18

18

Inspect for poor connections at the harness connector of the suspect air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step  25

Go to Step  23

19

Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step  25

Go to Step 22

20

Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step  25

Go to Step  24

21

Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement .

Did you complete the replacement?

--

Go to Step  25

--

22

Replace the sunload sensor. Refer to Sun Load Sensor Replacement .

Did you complete the replacement?

--

Go to Step  25

--

23

Important: Perform the recalibration procedure for the air temperature actuator.

Replace the suspect air temperature actuator. Refer to Temperature Actuator Replacement .

Did you complete the replacement?

--

Go to Step  25

--

24

Important:: Perform the recalibration procedure for the HVAC control module.

Replace the HVAC control module. Refer to Control Assembly Replacement .

Did you complete the replacement?

--

Go to Step  25

--

25

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step 3