Step
Action
Value(s)
Yes
No
1
Inspect fuse H7-H8.
Is the fuse open?
--
Go to Step 2
Go to Step 3
2
Repair a short to ground in circuit 301.
Is the repair complete?
Go to Diagnostic System Check - Lighting Systems
3
Repair a poor connection or an open in circuit 301 between the fuse block terminal H8 and S408.