Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: The IP compartment lamp does not turn ON when the IP compartment is open. | ||||
1 | Did you perform the Diagnostic System Check? | -- | Go to Step 2 | |
2 | Inspect the IP compartment lamp bulb filament. Is the IP compartment lamp bulb filament open? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the IP compartment lamp bulb. Is the repair complete? | -- | Go to Step 9 | -- |
4 |
Does the test light illuminate? | -- | Go to Step 5 | Go to Step 6 |
5 |
Does the test light illuminate? | -- | Go to Step 7 | Go to Step 8 |
6 | Repair a poor connection or an open in circuit 1450. Is the repair complete? | -- | Go to Step 9 | -- |
7 | Replace the IP compartment lamp switch. Is the repair complete? | -- | Go to Step 9 | -- |
8 | Repair a poor connection or an open in circuit 1732 between the IP compartment lamp and S242. Is the repair complete? | -- | Go to Step 9 | -- |
9 |
Is the repair complete? | -- | -- |