J 38778 Door Trim Clip Remover
Important: Insert a small flat-bladed tool and gently pry under the rear edge of the bolt covers.
Important: Push inward on the IP console support bracket in order to release the console top guide pins.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the front floor console front bolts to 6 N·m (53 lb in).
Tighten
Tighten the front floor console rear bolts to 6 N·m (53 lb in).
Tighten
Tighten the front floor console front side bolts to 5 N·m
(44 lb in).
Tighten
Tighten the front floor console bolts to 5 N·m (44 lb in).
Tighten
Tighten the front floor console storage compartment bolts to 5 N·m
(44 lb in).