The step below refers to the test step on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
Connector End View Reference: Engine Electrical Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 | Turn the ignition to the START position. Does the starter solenoid click only one time? | Go to Step 3 | |
Inspect the engine and the belt drive system for mechanical binding (seized engine, seized generator). Does the engine move freely? | Go to Step 4 | Go to Engine Will Not Crank - Crankshaft Will Not Rotate for the 3.5L (LX9) engine or Engine Will Not Crank - Crankshaft Will Not Rotate for the 3.6L (LY7) engine | |
4 | Test the battery positive voltage circuit between the battery and the starter motor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 5 |
5 | Test the ground circuit between the battery and the starter motor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 6 |
6 | Inspect for poor connections at the starter. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
7 | Replace the starter motor. Refer to Starter Motor Replacement . Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |