Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | Greater than 16°C (60°F) - 345 kPa (50 psi) Greater than 24°C (75°F) - 483 kPa (70 psi) Greater than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperature do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 197-225 kPa (29-33 psi) | 1100-1230 kPa (160-178 psi) | 9°C (48°F) |
19-23°C (66-75°F) | Below 40% | 191-228 kPa (28-33 psi) | 1060-1230 kPa (154-178 psi) | 10°C (50°F) |
Above 40% | 202-246 kPa (29-36 psi) | 1100-1370 kPa (160-199 psi) | 12°C (54°F) | |
24-29°C (76-85°F) | Below 35% | 194-230 kPa (28-33 psi) | 1130-1220 kPa (164-177 psi) | 11°C (52°F) |
35-60% | 198-246 kPa (29-36 psi) | 1090-1320 kPa (158-191 psi) | 12°C (54°F) | |
Above 60% | 236-311 kPa (34-45 psi) | 1140-1580 kPa (165-229 psi) | 15°C (59°F) | |
30-35°C (86-95°F) | Below 30% | 208-256 kPa (30-37 psi) | 1230-1370 kPa (178-199 psi) | 14°C (57°F) |
30-50% | 215-284 kPa (31-41 psi) | 1180-1540 kPa (171-223 psi) | 16°C (61°F) | |
Above 50% | 236-311 kPa (34-45 psi) | 1290-1750 kPa (187-254 psi) | 18°C (64°F) | |
36-40°C (96-105°F) | Below 20% | 235-298 kPa (34-43 psi) | 1340-1600 kPa (194-232 psi) | 17°C (63°F) |
20-40% | 246-315 kPa (36-46 psi) | 1340-1700 kPa (194-247 psi) | 18°C (64°F) | |
Above 40% | 260-348 kPa (38-51 psi) | 1410-1940 kPa (204-281 psi) | 21°C (70°F) | |
41-46°C (106-115°F) | Below 20% | 266-339 kPa (39-49 psi) | 1550-1820 kPa (225-264 psi) | 21°C (70°F) |
Above 20% | 280-369 kPa (41-54 psi) | 1530-2000 kPa (222-290 psi) | 23°C (73°F) | |
47-49°C (116-120°F) | Below 30% | 304-378 kPa (44-55 psi) | 1870-2020 kPa (271-293 psi) | 24°C (75°F) |