Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | ||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||
2 |
Does the scan tool indicate that the recirculation switch changes state? | -- | Go to Step 3 | Go to Step 11 | ||||||||||||
3 |
Does the test lamp illuminate? | -- | Go to Step 4 | Go to Step 8 | ||||||||||||
4 | Test the low reference circuit of the recirculation actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 5 | ||||||||||||
5 |
Does the voltage measure near the specified value? | 0 volts outside air | Go to Step 6 | Go to Step 7 | ||||||||||||
6 |
Does the voltage measure near the specified value? | 10-12 volts recirc | Go to Step 9 | Go to Step 7 | ||||||||||||
7 | Test the recirculation door control circuit of the recirculation actuator for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 10 | ||||||||||||
8 | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 14 | -- | ||||||||||||
9 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 10 | ||||||||||||
10 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 12 | ||||||||||||
11 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 13 | ||||||||||||
12 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||||||||
13 | Replace the HVAC control module. Refer to HVAC Module Assembly Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||||||||
14 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |