Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is ON while the HVAC control is in the OFF position. | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Disconnect the HVAC control module. Does the blower motor continue to operate? | Go to Step 4 | Go to Step 8 |
4 | Inspect or test the blower motor control circuit between the blower motor and the blower module for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 5 |
5 | Test the blower motor speed control circuit between the HVAC control module and blower motor control module for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 6 |
6 | Test the blower motor speed signal circuit for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 7 |
7 | Inspect for poor connections at the harness connector of the blower motor control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 9 |
8 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
9 | Replace the blower motor control module. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? | Go to Step 11 | -- |
10 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |