Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics Connector End View Reference: Master Electrical Component List | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Do both reading lamps illuminate? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Repair the high resistance or an open in the inoperative roof rail reading lamp courtesy lamps supply voltage supply or ground circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 4 | -- |
4 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |