Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.
- Disconnect the engine harness electrical connector from the electronic throttle control (ETC).
- Remove the thermostat bypass pipe. Refer to
Thermostat Bypass Pipes Replacement
.
- Remove the throttle body bolts.
- Remove the throttle body.
- Remove the throttle body gasket.
Notice: Do not use solvent of any type when cleaning the gasket surfaces on
the intake manifold and the throttle body assembly, as damage to the gasket
surfaces and throttle body assembly may result.
Use care in cleaning the gasket surfaces on the intake manifold and
the throttle body assembly, as sharp tools may damage the gasket surfaces.
- Clean and inspect the throttle body gasket mating surfaces.
Installation Procedure
- Install a NEW throttle body gasket, if necessary.
- Install the throttle body.
Notice: Refer to Fastener Notice in the Preface section.
- Install the throttle body bolts.
Tighten
Tighten the bolts to 10 N·m (89 lb in).
- Install the thermostat bypass pipe. Refer to
Thermostat Bypass Pipes Replacement
.
- Connect the engine harness electrical connector to the ETC.
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.