Removal Procedure
- Remove the right side instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages and Console.
- Disconnect the blower motor electrical connector.
- Remove the blower motor mounting screws.
- Remove the blower motor from the HVAC module assembly.
- Disconnect the electrical connector from the blower motor resistor assembly.
Important: Only loosen both of the forward blower resistor assembly mounting screws. The blower motor resistor assembly mounting holes are slotted.
- Loosen the forward blower resistor assembly mounting screws.
- Remove the rearward blower resistor assembly mounting screw.
- Remove the blower motor resistor assembly from the HVAC module assembly.
Installation Procedure
- Install the blower motor resistor assembly to the HVAC module assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the rearward blower resistor assembly mounting screw.
Tighten
Tighten all of the screws to 1.8 N·m (16 lb in).
- Connect the electrical connector to the blower motor resistor assembly .
- Install the blower motor to the HVAC module assembly.
- Install the blower motor mounting screws.
Tighten
Tighten the screws to 1.8 N·m (16 lb in).
- Connect the blower motor electrical connector.
- Install the right side instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages and Console.