Removal Procedure
- Remove the knee bolster. Refer to
Knee Bolster Replacement
.
Important: The HVAC controls must be set to the vent mode to position the defroster door lever for access to the air temperature actuator.
- Set the HVAC controls to the vent mode to position the defroster door lever.
- Remove the temperature door lever bolt (3) from the HVAC module.
- Disconnect and remove the temperature door lever spring (2).
- Disconnect and remove the temperature door lever (1) from the temperature door.
- Disconnect the air temperature actuator electrical connector.
- Remove the air temperature actuator mounting screws.
- Remove the air temperature actuator.
Installation Procedure
- Install the air temperature actuator.
Notice: Refer to Fastener Notice in the Preface section.
- Install the air temperature actuator mounting screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the air temperature actuator electrical connector.
Important: Align the pin on the air temperature actuator with the slot in the temperature door lever.
- Install the temperature door lever (1) to the temperature door.
- Connect the temperature door lever spring (2) to the temperature door lever (1) and HVAC module
case.
- Install the temperature door lever bolt (3) to the HVAC module case.
Tighten
Tighten the bolt to 0.9 N·m (8 lb in).
- Install the knee bolster. Refer to
Knee Bolster Replacement
.