Modules connected to the class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. Connecting a scan tool to the data link connector (DLC) allows communication with the modules for diagnostic purposes. DTCs may be set due to this symptom and during this diagnostic procedure. Complete the diagnostic procedure in order to ensure all the DTCs are diagnosed and cleared from memory.
• | The body control module (BCM) detects that the ignition is ON and sends the appropriate power mode message to the other modules. Therefore, the BCM must be connected to the DLC for any other module to communicate with the scan tool. |
• | When the class 2 serial data circuit: |
- | Is shorted to ground |
- | Is shorted to voltage |
The following DTCs may set:
• | U1300 |
• | U1301 |
• | U1305 |
The numbers below refer to the step numbers on the diagnostic table.
A partial loss of communication in the class 2 serial data circuit uses a different procedure than a total loss of communication of the class 2 serial data circuit.
The following DTCs may be retrieved with a history status. These DTCs are not the cause of the present condition.
• | U1300 |
• | U1301 |
• | U1305 |
A state of health (SOH) DTC with a history status may be present along with a U1000 or U1255 with a current status. This indicates that the malfunction occurred when the ignition was ON.
Normal class 2 serial data communication cannot take place until the power mode master (PMM) module sends the appropriate power mode message. If the PMM does not send a wake-up message, other modules on the class 2 serial data circuit may not communicate.
Normal class 2 serial data communication cannot take place until the PMM module sends the appropriate power mode message. If the PMM does not send a wake-up message, other modules on the class 2 serial data circuit may not communicate.
Normal class 2 serial data communication cannot take place until the power mode master (PMM) module sends the appropriate power mode message. If the PMM does not send a wake-up message, other modules on the class 2 serial data circuit may not communicate.
If there are no current DTCs that begin with the letter "U", the communication concern has been repaired.
The communication concern may have prevented diagnosis of the customer complaint.
Step | Action | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Data Communication Schematics Connector End View Reference: Master Electrical Component List | |||||||||||||||||||||||
1 | Does the scan tool power up? | Go to Step 2 | |||||||||||||||||||||
Does the scan tool communicate with any module on the class 2 serial data circuit? | Go to Step 3 | Go to Step 8 | |||||||||||||||||||||
3 |
Did you record any DTCs in the range of U1000 to U1305? | Go to Step 4 | Go to Step 7 | ||||||||||||||||||||
Are history DTCs U1300, U1301, or U1305 retrieved from any module? | Go to Step 5 | Go to Step 6 | |||||||||||||||||||||
5 |
Important: Turn ON the ignition, with the engine OFF, when testing for a short to voltage. Use the DMM MIN/MAX function to capture intermittent conditions. Test the class 2 serial data circuit for an intermittent short to ground or an intermittent short to voltage. Refer to the following: Did you find and correct the condition? | Go to Step 18 | Go to Step 6 | ||||||||||||||||||||
Are U1000 or U1255 the only DTCs displayed in the previously specified range? | Go to DTC U1000 and U1255 | Go to DTC U1001-U1254 | |||||||||||||||||||||
7 | Diagnose the non communicating module by using the DTC U1001-U1254 Lost Communications with XXX procedure for the module which is not communicating. The DTC U1001-U1254 Lost Communications with XXX procedure will determine which module is not communicating. Refer to DTC U1001-U1254 . Did you complete the action? | -- | |||||||||||||||||||||
8 |
Did you find and correct the condition? | Go to Step 9 | |||||||||||||||||||||
9 | Test the signal ground circuits of the DLC for an open or high resistance. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 10 | |||||||||||||||||||||
Does the scan tool communicate with the PMM? | Go to Step 12 | Go to Step 11 | |||||||||||||||||||||
11 |
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 18 | Go to Step 16 | ||||||||||||||||||||
Important: The PMM must remain connected to the DLC. Use the appropriate jumper, if needed.
Does the scan tool communicate with any module still connected to the class 2 serial data circuit after the splice pack was disconnected? | Go to Step 13 | Go to Step 14 | |||||||||||||||||||||
Important: The PMM must remain connected to the DLC. Use the appropriate jumper, if needed. Using the appropriate jumper at the splice pack, perform the following in order to determine which class 2 serial data circuit or module is causing the concern:
Did you complete the action? | Go to Step 15 | -- | |||||||||||||||||||||
14 | Repair the short to ground or voltage condition in the class 2 serial data circuits or in-line connectors to the last module connected in the branch being diagnosed. Refer to Wiring Repairs and Connector Repairs . Did you complete the repair? | Go to Step 18 | -- | ||||||||||||||||||||
15 | Test the class 2 serial data circuits to the suspect module for a short to ground or a short to voltage. Turn ON the ignition, with the engine OFF when testing for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 18 | Go to Step 16 | ||||||||||||||||||||
16 | Inspect for poor connections and terminal tension at the harness connector of the suspect module. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs . Did you find and correct the condition? | Go to Step 18 | Go to Step 17 | ||||||||||||||||||||
17 | Replace the suspect module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 18 | -- | ||||||||||||||||||||
18 |
Important: The scan tool may require a power up reset before communication will occur due to a short on the class 2 serial data circuit. Turn OFF or disconnect the scan tool before you display DTCs. Did your record any DTCs which begin with a letter "U" and with a current status? | Go to Step 20 | Go to Step 19 | ||||||||||||||||||||
Did you record any DTCs which do not begin with a letter "U"? | Go to Step 20 | Go to Step 21 | |||||||||||||||||||||
Diagnose the DTCs as directed by the diagnostic procedures for the particular module or concern. Did you complete the action? | Go to Step 21 | -- | |||||||||||||||||||||
21 | Did you diagnose all of the DTCs? | Go to Step 22 | Go to Step 20 | ||||||||||||||||||||
22 | Clear the DTCs using the scan tool. Did you complete the action? | -- |